DL-K contactors 4…18,5 kW DL-K4-…DL-K18 2019-08-30T12:29:13+00:00

DL-K contactors
4…18,5 kW
DL-K4-…DL-K18

Type variants

Types Switchable motor-power
Pe [kW] (AC-3, 400 V)
Thermal current
Ith [A] without enclosure
Thermal current
Ithe [A] with eclosure
DL-K4-10
DL-K4-01
4 22 16
DL-K5-10
DL-K5-01
5,5 25 20
DL-K7-10
DL-K7-01
7,5 32 25
DL-K11-10
DL-K11-01
11 32 30
DL-K15 15 54 45
DL-K18 18,5 54 50

Type variants

Switchable motor-power
Pe [kW] (AC-3, 400 V)
DL-K4-10
DL-K4-01
4
DL-K5-10
DL-K5-01
5,5
DL-K7-10
DL-K7-01
7,5
DL-K11-10
DL-K11-01
11
DL-K15 15
DL-K18 18,5
Thermal current
Ith [A] with eclosure
DL-K4-10
DL-K4-01
22
DL-K5-10
DL-K5-01
25
DL-K7-10
DL-K7-01
32
DL-K11-10
DL-K11-01
32
DL-K15 54
DL-K18 54
Thermal current
Ithe [A] with eclosure
DL-K4-10
DL-K4-01
16
DL-K5-10
DL-K5-01
20
DL-K7-10
DL-K7-01
25
DL-K11-10
DL-K11-01
30
DL-K15 45
DL-K18 50

Arrangements of contacts and types of  DC control

HL-K-XX Auxiliary contactors
HL-K(G)-XX Auxiliary contactors with DC control
DL-K(G)Y-XX Contactors with DC control
DL-KYF Contactors with 4 making contacts
DL-KYF/s Contactors with 4 making and 2 breaking contacts

Note: The type-code of contactors consists the switchable motor power and after the hyphen the quantity of the built-in free usable normally open (NO) and normally closed (NC) auxiliary contacts. The Y refers type size.

Arrangements of contacts and types of  DC control

HL-K-XX:
Auxiliary contactors
HL-K(G)-XX:
Auxiliary
contactors with
DC control
DL-K(G)Y-XX:
Contactors
with DC control
DL-KYF:
Contactors
with 4 making
contacts
DL-KYF/s:
Contactors with
4 making and
2 breaking contacts

Note: The type-code of contactors consists the switchable motor power and after the hyphen the quantity of the built-in free usable normally open (NO) and normally closed (NC) auxiliary contacts. The Y refers type size.

Accessories

Snaps to the front-side:

  • Auxiliary contact-block with two or four contacts
  • Star-delta timer module

To coil terminals on the upper side:

  • over-voltage monitor or suppressor module
  • Low-signal connecting unit

Side mounting:

  • auxiliary contact-block with two contacts
  • mechanical interlock for avoid the simultaneous operation of two contactors

To lower terminals plugging:

  • thermal (overload) relay; 0,2…32A (13 stages)

Operation:

  • AC (12…600 V 50/60 Hz) coils, or DC (12…250 V) coils
  • AC or DC main current paths
  • Easy-to-wire three terminals (upper: A1 and A2- lower: A2)

Operational and environmental safety:

  • Degree of protection IP 20 (finger-protected terminals against accidental touching)
  • Cadmium-free contacts, asbest-free plastic parts, environmental-friendly materials

Aesthetic design and colour composition

Relevant standard: EN 60947-4-1
The detailed technical description of the product family is in the catalogue:
CONTACTORS FROM 2,2 … 132 kW“.
For further information contact with product manager György Lieli
lieli.gyorgy@ganzkk.hu
or engineer Lajos Holczbauer
holczbauer.lajos@ganzkk.hu